Modify Entrust legacy token settings

Legacy tokens are older model tokens supported by Entrust Identity Enterprise (formerly Entrust IdentityGuard). Identity as a Service supports legacy tokens for the migration of  Entrust Identity Enterprise users to the cloud.

Modify Entrust Legacy token

1.      Click > Policies > Authenticators. The Authenticators page appears.  

2.      Select Entrust Legacy Token. The Entrust Legacy Token settings appears.

3.      Set the Max. Time Steps that a token response is valid for during normal authentication. This setting defines the number of time steps that are searched to find a matching user response during authentication. A value of 1 equates to 30 seconds. The default value is 10, or 300 seconds.

4.      Set Max Reset Clock Window to the number of minutes that Identity as a Service searches to find a matching user response during a token reset operation. The value must be between 1 and 120 (or two hours). The default value is 10 minutes.

5.      Set Max Event Window to the numbers of token responses that are searched to find a matching user response during authentication. The value entered must be less than the Max Reset Event Window. The value must be between 10 and 200, in increments of 10. The default value is 100.

6.      Set Max Reset Event Window to the number of token responses that are searched to find a matching user response during a token reset operation. The value must be between 10 and 5000, in increments of 10. The default value is 100.

7.      Click Save.